Valid HPE2-W09 Test Answers & HP HPE2-W09 Exam PDF [Q29-Q47]

Share

Valid HPE2-W09 Test Answers & HP HPE2-W09 Exam PDF

HP HPE2-W09 Certification Real 2024 Mock Exam


The Aruba Data Center Network Specialist Exam certification exam features question formats such as multiple-choice, scenario-based, and drag-and-drop. HPE2-W09 exam duration is 1 hour and 30 minutes, and the passing score is 70%. Before taking the exam, it is essential to have a working knowledge of Aruba data center networking.

 

NEW QUESTION # 29
Does this correctly describe NetEdit's notification capabilities?
Solution: NetEdit notifies admins of errors using Its Internal email server.

  • A. No
  • B. Yes

Answer: A

Explanation:
NetEdit is a network management tool that allows you to configure, monitor, and troubleshoot ArubaOS-CX switches. NetEdit can send notifications of changes in network conditions to other services, such as email, using methods that define the service type and credentials. However, NetEdit does not use its internal email server to send notifications. NetEdit requires an external SMTP server to send email notifications, and the SMTP server address, port, username, and password must be configured in the email method1. Therefore, this does not correctly describe NetEdit's notification capabilities.


NEW QUESTION # 30
Refer to the exhibits.


Is this how the switch handles the traffic?
Solution: A broadcast arrives in VLAN 10 on Switch-1. Switch 1 forwards the frame on all interfaces assigned to VLAN10, except the incoming interface. It encapsulates the broadcast with VXIAN and sends it to 192.168.1.2. but not 192.168.1.3.

  • A. Yes
  • B. No

Answer: A


NEW QUESTION # 31
You want to use NetEdit to configure an AtubaOS-CX switch.
Is this a minimum requirement for setting up communications between the switch and NetEdit?
Solution: Enable the REST interface in read-only mode.

  • A. No
  • B. Yes

Answer: A

Explanation:
The solution is incorrect because enabling the REST interface in read-only mode is not a minimum requirement for setting up communications between the switch and NetEdit. NetEdit uses the REST interface to configure the switch, so it needs write access as well as read access. Therefore, enabling the REST interface in read-write mode is a minimum requirement for setting up communications between the switch and NetEdit.


NEW QUESTION # 32
You plan to use multi-protocol BGP to implement dynamic VRF route leaking on an ArubaOS-CX switch.
Is this a rule for the setup?
Solution: You can only leak routes between up to three VRFs.

  • A. No
  • B. Yes

Answer: A

Explanation:
You can only leak routes between up to three VRFs is not a rule for the setup of multi-protocol BGP to implement dynamic VRF route leaking on an ArubaOS-CX switch. There is no limit on the number of VRFs that can participate in route leaking using multi-protocol BGP. You can configure multiple import and export route targets for each VRF and leak routes between any VRFs that have matching route targets1.


NEW QUESTION # 33
Your customer is using Nutanix AHV and they need a network orchestration tool to simplify network provisioning. Is this operation supported when Aruba Fabric Composer (AFC) is integrated with Nutanix?
Solution: Automated configuration of Layer 3 MP-BGP protocol on leaf switches

  • A. No
  • B. Yes

Answer: A

Explanation:
Automated configuration of Layer 3 MP-BGP protocol on leaf switches is not an operation supported when Aruba Fabric Composer (AFC) is integrated with Nutanix. AFC is a tool that provides automation and orchestration for managing data center networks composed of ArubaOS-CX switches. AFC can integrate with various data center software such as VMware vSphere, Nutanix AHV, Microsoft Hyper-V, etc. AFC can discover, monitor, and configure Nutanix AHV clusters and hosts using REST APIs. However, AFC does not support the configuration of Layer 3 MP-BGP protocol on leaf switches, which is required for EVPN VXLAN networks. AFC only supports the configuration of Layer 2 VXLAN networks without EVPN1.


NEW QUESTION # 34
Refer to the exhibit.

You need to set up an ArubaOS-CX switch to implement Virtual Extensible LAN (VXLAN) WITHOUT Ethernet VPN (EVPN). The exhibit Indicates which servers should be part of the same VXLANs and the desired VNls for the VXLANs. Assume that the network is already configured to permit each ArubaOS-CX switch to reach each other switch's loopback interface.
Is this part of the process for setting up VXLAN to meet the requirements?
Solution: On Switch-1, set 192.168.1.3 as a peer IP address in the VNI 5020 context.

  • A. Yes
  • B. No

Answer: A

Explanation:
On Switch-1, set 192.168.1.3 as a peer IP address in the VNI 5020 context is part of the process for setting up VXLAN to meet the requirements of enabling servers to be part of the same VXLANs and VNIs as shown in the exhibit. Switch-1, Switch-2, and Switch-3 are ArubaOS-CX switches that use VXLAN to provide Layer 2 extension over Layer 3 networks without EVPN. VXLAN is a feature that uses UDP encapsulation to tunnel Layer 2 frames over Layer 3 networks using VNIs. To set up VXLAN without EVPN on Switch-1, you need to do the following steps:
Configure loopback interfaces with IP addresses on each switch
Configure VLAN interfaces with IP addresses on each switch
Configure VXLAN interfaces with VNIs on each switch
Configure peer IP addresses for each VNI on each switch
Configure static routes or dynamic routing protocols to enable reachability between loopback interfaces On Switch-1, setting 192.168.1.3 as a peer IP address in the VNI 5020 context means that Switch-1 can send and receive VXLAN traffic for VNI 5020 to and from Switch-2, which has the loopback interface with IP address 192.168.1.3.


NEW QUESTION # 35
Is this a best practice when positioning ArubaOS-CX switches in data center networks?
Solution: Deploy Aruba CX 6300 switches as data center spine switches.

  • A. No
  • B. Yes

Answer: A

Explanation:
Deploy Aruba CX 6300 switches as data center spine switches is not a best practice when positioning ArubaOS-CX switches in data center networks. The Aruba CX 6300 switches are designed for data center leaf roles, and they provide high density, low latency, and advanced features such as VSX and EVPN. The Aruba CX 83xx switches are more suitable for data center spine roles, and they provide high performance, scalability, and resiliency1.


NEW QUESTION # 36
You enter this command on an ArubaOS-CX switch:
Switch# show erps status ring 1
Is this what the specified status means?
Solution: The status is Protection, which means that the ring is up and fully connected with the RPL port blocked.

  • A. No
  • B. Yes

Answer: A


NEW QUESTION # 37
Can you attach this type of ArubaOS-CX interface to a VRF?
Solution: A loopback interface

  • A. No
  • B. Yes

Answer: A

Explanation:
A loopback interface can be attached to a VRF on an ArubaOS-CX switch. A loopback interface is a virtual interface that has an IP address assigned to it and is always up. A loopback interface can be attached to a VRF by using the vrf attach command under its configuration mode1.


NEW QUESTION # 38
Does this correctly describe the ArubaOS-CX architecture?
Solution: The ArubaOS-CX time-series database helps to support network analytics and troubleshooting.

  • A. Yes
  • B. No

Answer: A

Explanation:
The ArubaOS-CX time-series database helps to support network analytics and troubleshooting is a correct description of the ArubaOS-CX architecture. The time-series database (TSDB) is a component of the ArubaOS-CX software that stores information about the switch's configuration, status, and performance over time. The TSDB helps to support network analytics and troubleshooting by providing historical data and trend analysis for various metrics1.


NEW QUESTION # 39
Refer to the exhibits.


Is this how the switch-1 handles the traffic?
Solution: A broadcast arrives in VLAN 10 on Switch-1. Switch 1 forwards the frame on all interfaces assigned to VLAN 10, except the incoming interface. It encapsulates the broadcast with VXIAN and sends it to 192.168.1.3, out not 192.168.1.2.

  • A. Yes
  • B. No

Answer: A


NEW QUESTION # 40
You want to use NetEdit to configure an AtubaOS-CX switch.
Is this a minimum requirement for setting up communications between the switch and NetEdit?
Solution: Make sure that the SSH server is enabled.

  • A. Yes
  • B. No

Answer: A

Explanation:
The solution is correct because making sure that the SSH server is enabled is a minimum requirement for setting up communications between the switch and NetEdit. NetEdit uses SSH to establish a secure connection to the switch and execute commands on it. Therefore, making sure that the SSH server is enabled is necessary for setting up communications between the switch and NetEdit.


NEW QUESTION # 41
A customer's servers use ISCSI, and they send data and storage traffic on the same pair of I OGbE links. Is this a best practice for supporting the ISCSI requirements?
Solution: Use Virtual Routing and Forwarding (VRF) to tunnel iSCSI traffic through the network spine on the same links that data traffic uses.

  • A. No
  • B. Yes

Answer: A

Explanation:
ISCSI is a protocol that allows storage devices to communicate over IP networks. ISCSI traffic has different requirements than data traffic, such as low latency, high throughput, and reliability. Therefore, it is not a best practice to send data and storage traffic on the same pair of 10GbE links, as this can cause congestion and performance degradation. It is also not a best practice to use Virtual Routing and Forwarding (VRF) to tunnel ISCSI traffic through the network spine on the same links that data traffic uses. VRF is a technology that creates multiple isolated Layer 3 domains on a physical network, each with its own routing table. VRF does not provide any benefits for ISCSI traffic, as it does not guarantee bandwidth, priority, or quality of service. VRF also adds overhead and complexity to the network configuration1. Therefore, this is not a valid way to support the ISCSI requirements.


NEW QUESTION # 42
You are configuring Ethernet Ring Protection Switching (ERPS) on an ArubaOS-CX switch. Is this a guideline for configuring timers?
Solution: The guard interval is set in units of seconds and is used to prevent frequent topology changes due to a link going up and down.

  • A. No
  • B. Yes

Answer: A


NEW QUESTION # 43
You are using NetEdit to manage AruDaOS-CX switches. You want to deploy a standard config to the switches, but need the config to include a few device-specific settings such as hostname and IP address.
Is this what you should do?
Solution: Create two configuration plans, one with the standard config and one with the device-specific settings.

  • A. No
  • B. Yes

Answer: A

Explanation:
Creating two configuration plans, one with the standard config and one with the device-specific settings, is not what you should do. NetEdit is a tool that allows you to manage and monitor multiple switches from a single interface1. It also provides a plan feature that lets you create containers to group devices and execute operations on them, such as deploying, committing, or rolling back device configuration or firmware1. However, you do not need to create two configuration plans for your scenario. You can create one configuration plan with the standard config and use variables to define the device-specific settings1. Variables are placeholders that can be replaced with different values for different devices1. This way, you can deploy a standard config with device-specific settings using one configuration plan1.


NEW QUESTION # 44
Does this correctly describe Network Analytics Engine (NAE) limitations on ArubaOS-CX switches?
Solution: Different switches have different limitations for the number of NAE scripts, monitors, and agents supported.

  • A. No
  • B. Yes

Answer: A


NEW QUESTION # 45
AtubaOS-CX switches are acting as Virtual Extensible LAN (VXLAN) Tunnel Endpoints (VTEPs) WITHOUT Ethernet VPN (EVPN).
Does this correctly describe how the VTEPs handle VXLAN traffic forwarding?
Solution: VTEPs that use headend replication forward broadcast as multicast to each VTEP in the same VNI.

  • A. Yes
  • B. No

Answer: A

Explanation:
VXLAN is a tunneling protocol that encapsulates layer 2 traffic over an IP network using VXLAN Network Identifiers (VNIs) to identify different layer 2 segments. VXLAN Tunnel Endpoints (VTEPs) are devices that perform the encapsulation and decapsulation of VXLAN packets. VTEPs can use different methods to handle broadcast, unknown unicast, and multicast (BUM) traffic within a VNI. One of these methods is headend replication, which means that the VTEP that receives a BUM packet replicates it and sends it as a unicast to each remote VTEP in the same VNI1. This method does not require multicast routing in the underlay network, but it can increase the load on the ingress VTEP. Therefore, this correctly describes how the VTEPs handle VXLAN traffic forwarding without EVPN.


NEW QUESTION # 46
Refer to the exhibit.

which shows the topology tot an Ethernet Ring Protection Switching (ERPS) solution.
Is this a valid design for the control and protected VLANs on the VSX fabric 1 switches?
Solution: Ring 1, instance 1:
control VLAN: 1000protected VLANs: 51-135 Ring l,Instance2:
control VLAN: 1001 protected VLANs: 136-220 Ring 2, Instance 1: control VLAN: 1000 protected VLANs: 181 -200 Ring 2, Instance 2: control VLAN: 1003 protected VLANs: 201 -220

  • A. No
  • B. Yes

Answer: A


NEW QUESTION # 47
......

HPE2-W09 Exam Questions and Valid HPE2-W09 Dumps PDF: https://www.prepawaypdf.com/HP/HPE2-W09-practice-exam-dumps.html

HPE2-W09 Brain Dump: A Study Guide with Tips & Tricks for passing Exam: https://drive.google.com/open?id=1tUD-ATwwUBO4QCg46b4SdKueqjerqxP4