Verified LEED-AP-O-M dumps Q&As - Pass Guarantee or Full Refund [Sep-2024]
LEED-AP-O-M PDF Dumps | Sep 01, 2024 Recently Updated Questions
NEW QUESTION # 70
The intent of the Energy and Atmosphere Credit, Enhanced Refrigeration Management is to reduce ozone depletion and support early compliance with the
- A. Montreal Protocol while minimizing direct and indirect contributions to climate change
- B. Montreal Protocol while minimizing direct contributions to climate change
- C. Kyoto Protocol while minimizing direct contributions to climate change
- D. Kyoto Protocol while minimizing direct and indirect contributions to climate change
Answer: A
Explanation:
The intent of the Energy and Atmosphere Credit, Enhanced Refrigeration Management, is to reduce ozone depletion in alignment with the Montreal Protocol while also minimizing both direct and indirect contributions to climate change. This credit focuses on the management of refrigerants used in HVAC systems, promoting the use of substances with lower global warming potentials and better refrigerant management practices to reduce environmental impacts.
References:The LEED AP Operations + Maintenance reference materials explain the significance of the Montreal Protocol in the context of refrigerant management and its role in mitigating climate change, underscoring the dual focus of this credit on both ozone protection and climate change mitigation.
NEW QUESTION # 71
In the calculations for Water Efficiency Prerequisite, Indoor Water Use Reduction, private use refers to lavatory faucets used by which of the following types of occupants?
- A. Dorm residents, fire-station staff, nursing home staff
- B. Students, hospital staff, hotel guests
- C. Prisoners, hospital inpatients, hotel staff
- D. Apartment residents, motel guests, nursing home residents
Answer: D
Explanation:
This answer is correct because private use refers to lavatory faucets that are not for common use and are intended for the exclusive use of specific occupants.According to the LEED v4 Indoor Water Use Reduction Calculator1, private use applies to the following types of occupants: apartment residents, motel guests, nursing home residents, and dorm residents. The other options are incorrect because they either include common use lavatory faucets (such as prisoners, hospital staff, hotel guests, and fire-station staff) or do not include lavatory faucets at all (such as hospital inpatients and hotel staff).
References: =LEED v4 Indoor Water Use Reduction Calculator;LEED v4 water efficiency credits: Do you know the new standards?;LEED QUALIFICATION GUIDE - v4 - Sloan
NEW QUESTION # 72
Storage locations are required for which of the following recyclable materials?
- A. Mixed paper, corrugated cardboard, wood pallets, plastics and metals
- B. Mixed paper, paint, glass, plastics and electronics
- C. Mixed paper, batteries, glass, plastics and electronics
- D. Mixed paper, corrugated cardboard, glass, plastics and metals
Answer: D
Explanation:
This is the correct answer because LEED v4.1 O+M requires projects to provide storage locations for at least five of the following recyclable materials: mixed paper, corrugated cardboard, glass, plastics, metals, batteries, mercury-containing lamps, and electronic waste. Option D lists five of these materials, while the other options include materials that are not required by LEED, such as paint, wood pallets, or electronics.
References:
*LEED v4.1 O+M Reference Guide, p. 1211
*LEED v4.1 O+M Guide, p. 92
NEW QUESTION # 73
At a minimum, which two factors must be continuously monitored by the system in order to achieveIndoor Environmental Quality Credit, Thermal Comfort?
- A. Air speed and air temperature
- B. Humidity and air temperature
- C. Radiant temperature and air speed
- D. Air speed and humidity
Answer: B
Explanation:
For the Indoor Environmental Quality Credit, Thermal Comfort, the system must continuously monitor both humidity and air temperature. These two factors are crucial for maintaining thermal comfort within the building environment.
References: The LEED v4.1 O+M reference materials specify the importance of monitoring humidity and air temperature as part of the requirements for achieving the Thermal Comfort credit12.
To achieve the Indoor Environmental Quality Credit, Thermal Comfort, the system must continuously monitor at least two key factors: humidity and air temperature. These factors are critical for maintaining thermal comfort within a building, as they directly affect the perceived comfort levels of the occupants. Proper monitoring and management of humidity and air temperature ensure that the indoor environment remains within comfortable ranges for occupants, contributing to their well-being and productivity.
References:This requirement is specified in the LEED AP Operations + Maintenance reference guide within the section on Indoor Environmental Quality Credit, Thermal Comfort. The guide emphasizes the importance of maintaining optimal levels of humidity and air temperature for achieving thermal comfort in indoor spaces.
NEW QUESTION # 74
A project is using an on-site captured rainwater system and municipally treated wastewater for both flush fixtures and irrigation. To which of the following Water Efficiency prerequisites or credits can these alternative water sources be applied?
- A. The on-site captured rainwater system may only be applied to Water Efficiency Credit, Indoor Water Use Reduction, while the municipally treated wastewater may only be applied to Water Efficiency Credit, Outdoor Water Use Reduction
- B. Both alternative water sources may only be applied towards the credits for both Indoor Water Use Reduction and Outdoor Water Use Reduction
- C. Both alternative water sources may only be applied towards the prerequisites for both Indoor Water Use Reduction and Outdoor Water Use Reduction
- D. The on-site captured rainwater may only be applied to Water Efficiency Prerequisite, Indoor Water Use Reduction while the municipally treated wastewater may only be applied to Water Efficiency Prerequisite, Outdoor Water Use Reduction
Answer: B
Explanation:
Using on-site captured rainwater and municipally treated wastewater for both flush fixtures and irrigation can be applied towards the credits for both Indoor Water Use Reduction and Outdoor Water Use Reduction in LEED. These alternative water sources contribute to the overall water efficiency of the project by reducing the reliance on potable water sources for indoor and outdoor uses.
NEW QUESTION # 75
Which of the following is the most appropriate use of untreated stormwater?
- A. Drinking fountain
- B. Cooling water makeup
- C. Irrigation
- D. Boiler water makeup
Answer: C
Explanation:
Untreated stormwater, due to its potential contaminants, is not suitable for potable uses but can be effectively utilized for non-potable applications such as irrigation. It provides a viable alternative to using treated water for landscape irrigation, thereby conserving potable water resources. This use aligns with sustainable water management practices encouraged by LEED, which promote the reduction of potable water usage for landscape irrigation.
References:
* The LEED Reference Guide for Green Building Design and Construction and the LEED O+M Reference Guide both encourage the use of untreated stormwater for irrigation as part of an integrated water management approach. This conservation strategy is covered under the Water Efficiency category and is a common topic in LEED AP O+M training sessions.
NEW QUESTION # 76
Who is the best person to serve as the Indoor Environmental Quality Manager to successfully implement Indoor Environmental Quality Credit, Indoor Environmental Quality Management Program?
- A. A commissioning (Cx) agent
- B. The LEED AP
- C. A general contractor
- D. The building engineer
Answer: D
Explanation:
The building engineer is ideally positioned to serve as the Indoor Environmental Quality Manager for implementing the Indoor Environmental Quality Credit, Indoor Environmental Quality Management Program.
Their expertise in building systems and operations ensures that indoor environmental quality strategies are effectively integrated into the building's daily maintenance and operation procedures, enhancing the well-being of occupants.
References:The role and responsibilities of the Indoor Environmental Quality Manager in implementing the Indoor Environmental Quality Management Program are detailed in the LEED AP Operations + Maintenance reference materials. These resources underline the importance of having a dedicated professional, like a building engineer, oversee indoor environmental quality initiatives.
NEW QUESTION # 77
Who needs to be surveyed for an in-patient hospital project for Location and Transportation Credit, Alternative Transportation: Option 1. Transportation Survey?
- A. Patients being released
- B. Pharmaceutical representatives
- C. People visiting patients
- D. Hospital employees
Answer: D
NEW QUESTION # 78
Which of the following topics is unnecessary in order to comply with the Sustainable Sites Credit, Site Improvement Plan?
- A. Hydrology
- B. Maintenance equipment
- C. Soils
- D. Vegetation
Answer: B
Explanation:
The correct answer is D because maintenance equipment is not a topic that is required to be addressed in the Site Improvement Plan for the Sustainable Sites Credit, as stated in the LEED v4.1 O+M Reference Guide1.The Site Improvement Plan must include topics such as soils, hydrology, vegetation, and site management, and describe the existing conditions, goals, strategies, and performance metrics for each topic1.
The other optionsare incorrect because they are topics that are required to be addressed in the Site Improvement Plan.
References: =
* LEED v4.1 O+M Reference Guide, page 115
* Guide to the LEED AP Operations and Maintenance (O+M) Exam, page 80
* LEED v4 AP O+M Mock Exam, page 86 =========================================
NEW QUESTION # 79
What is the maximum length of time allowed for a gap in performance monitoring before needing to restart the performance period?
- A. Two full weeks
- B. One full week
- C. Three full weeks
- D. Four full weeks
Answer: A
Explanation:
In LEED, for maintaining continuous performance monitoring, the maximum length of time allowed for a gap before needing to restart the performance period is two full weeks. This requirement ensures that performance data is consistent and reliable, providing an accurate representation of the building's operational performance.
NEW QUESTION # 80
A cafeteria purchases $325.00 USD worth of United States Department of Agriculture (USDA) Organic Certified produce from a farm located 50 mi. (80 km) from the project building during the performance period.
What is the maximum allowable value for this purchase that can be claimed towards Materials and Resources Credit, Purchasing- Ongoing?
- A. $650.00 USD
- B. $0.00 USD
- C. $162.50 USD
- D. $325.00 USD
Answer: D
Explanation:
The full value of the purchase can be claimed towards the credit because it meets the criteria for sustainable purchasing under LEED O+M v4.1. The produce is USDA Organic Certified and sourced from within 100 miles of the project, which qualifies for the local economy and environment category.
References: The LEED AP O+M Reference Guide provides detailed information on the requirements for the Materials and Resources Credit, Purchasing - Ongoing, including the emphasis on sustainable purchasing and supporting local economies12.
For the Materials and Resources Credit, Purchasing - Ongoing, the full value of $325.00 USD spent on USDA Organic Certified produce from a local farm (within 100 miles or 160 kilometers) can be claimed. This is because the LEED criteria for sustainable purchasing recognize and reward the procurement of local and organic food products to support sustainable agricultural practices and reduce transportation impacts. The entire amount spent on these products contributes towards the credit because it aligns with the goals of supporting local economies and reducing environmental impacts associated with long-distance food transportation.
References:The LEED AP Operations + Maintenance reference materials detail the criteria for sustainable purchasing, including the emphasis on local and organic food procurement. These guidelines specify how purchases like these contribute towards achieving the Materials and Resources Credit, Purchasing - Ongoing.
NEW QUESTION # 81
Which of the following parameters need to be continuously monitored for occupied spaces in order to qualify for Indoor Environmental Quality Credit, Thermal Comfort?
- A. Radiant temperature and energy consumption
- B. Air temperature and humidity
- C. Air speed and radiant temperature
- D. Air temperature and energy consumption
Answer: B
Explanation:
The Indoor Environmental Quality Credit for Thermal Comfort under the LEED AP Operations + Maintenance (LEED AP O+M) V4.1 requires continuous monitoring of certain parameters in occupied spaces.
Among the options provided, air temperature and humidity are the parameters that need to be continuously monitored. These parameters are crucial in maintaining a comfortable thermal environment for building occupants.
References: LEED v4: Building Operations + Maintenance Guide, LEED AP with specialty
NEW QUESTION # 82
Evapotranspiration data is applied to what credit?
- A. Water Efficiency Credit, Outdoor Water Use Reduction
- B. Energy and Atmosphere Credit, Enhanced Refrigerant Management
- C. Location and Transportation Credit, Alternative Transportation
- D. Water Efficiency Credit, Cooling Tower Water
Answer: A
NEW QUESTION # 83
In order to determine the transportation patterns of occupants of a typical office building, a survey requesting data from what period of time should be administered to meet the requirements of the Location and Transportation Credit, Alternative Transportation?
- A. 10 days
- B. 14 days
- C. Three days
- D. Five days
Answer: D
Explanation:
The LEED AP Operations + Maintenance (LEED AP O+M) V4.1 guidelines for the Location and Transportation Credit, Alternative Transportation, suggest conducting a survey to determine the transportation patterns of occupants of a typical office building. The survey should request data from a period of five days. This duration is considered sufficient to provide a representative sample of the typical commuting patterns and behaviors of the building occupants1.
References:
* Alternative transportation | U.S. Green Building Council
NEW QUESTION # 84
Rainwater harvesting can be used for which of the following credits or prerequisites?
- A. Water Efficiency Credit, Water Metering
- B. Water Efficiency Credit, Indoor Water Use Reduction
- C. Water Efficiency Prerequisite, Indoor Water Use Reduction
- D. Water Efficiency Prerequisite, Building-Level Water Metering
Answer: A
NEW QUESTION # 85
The project team has been directed by the building owner to only pursue practices that directly improve the actual building performance. Which of the following would be the lowest cost option?
- A. Provide financial support for off-site conservation
- B. Install new high efficiency urinal flush valves
- C. Purchase renewable energy credits
- D. Install a new high-efficiency chiller
Answer: B
NEW QUESTION # 86
Which of the following strategies improves cooling tower water efficiency?
- A. Install and maintain a conductivity meter
- B. Increase cooling tower fan speed
- C. Lower set point of water leaving cooling tower
- D. Increase the cooling tower blowdown
Answer: A
Explanation:
Installing and maintaining a conductivity meter is a strategy that improves cooling tower water efficiency.
Conductivity meters help optimize the cycles of concentration, reducing water and chemical use by accurately measuring the water's mineral content.
References: The LEED v4.1 O+M reference materials recommend the use of conductivity meters as part of water efficiency best management practices for cooling towers1234.
NEW QUESTION # 87
Under Indoor Environmental Quality Credit, Interior Lighting, outlet powered task lighting contributes towards compliance for what category of building space?
- A. Mechanical
- B. Individual occupant
- C. Lavatory
- D. Exterior
Answer: B
Explanation:
Outlet powered task lighting under the Indoor Environmental Quality Credit, Interior Lighting, contributes towards compliance for individual occupant spaces. This is because task lighting allows individual occupants to control their own lighting levels, which can improve comfort and productivity.
References: LEED v4: Building Operations + Maintenance Guide1, LEED certification for existing buildings and spaces2.
NEW QUESTION # 88
Which of the following is considered an ongoing purchase for the purpose of calculating Materials and Resources Credit, Solid Waste Management - Ongoing?
- A. Toner cartridges
- B. Mercury-containing lamps
- C. Shelving units
- D. Office chairs
Answer: A
Explanation:
Toner cartridges are considered an ongoing purchase, as they are consumable items that are regularly replaced as part of the normal operation and maintenance of the building. The other options are not ongoing purchases, as they are durable goods that are not frequently replaced or disposed of.
References: =
* LEED v4.1 O+M Guide, page 48
* Solid waste management - ongoing, U.S. Green Building Council
* Guide to the LEED AP Operations and Maintenance (O+M) Exam, page 157
NEW QUESTION # 89
What is the maximum number of points possible for the Exemplary Performance option of the Innovation Credit, Innovation?
Calculator
- A. 2 points
- B. 1 point
- C. 4 points
- D. 3 points
Answer: A
Explanation:
The maximum number of points possible for the Exemplary Performance option of the Innovation Credit, Innovation in LEED AP O+M v4.1 is 2 points. This is part of the overall potential to earn up to 5 points in the Innovation category, which can include pilot credits, innovation credits, and exemplary performance credits.
References: The LEED credit library and other resources provide information on the point distribution for various credits within the LEED system, including the Innovation Credit, Innovation1.
For the Exemplary Performance option of the Innovation Credit, Innovation, the maximum number of points possible is two. This option is designed to recognize and incentivize projects that achieve performance levels significantly beyond the prerequisite standard or credit requirements in the LEED rating system.
NEW QUESTION # 90
What credit rewards customers who change their normal consumption patterns in response to the varying price of energy over time?
- A. Energy and Atmosphere Credit, Advanced Energy Metering
- B. Energy and Atmosphere Credit, Demand Response
- C. Energy and Atmosphere Credit, Green Power and Carbon Offsets
- D. Energy and Atmosphere Credit, Ongoing Commissioning
Answer: B
Explanation:
The LEED AP Operations + Maintenance (LEED AP O+M) V4.1 rewards customers who change their normal consumption patterns in response to the varying price of energy over time under the Energy and Atmosphere Credit, Demand Response. This credit encourages building owners and operators to participate in demand response programs which aim to shift the timing of energy use to off-peak periods when demand on the grid is lower. This helps to reduce the strain on the grid during peak demand periods, potentially avoiding the need for additional power plants.
References: LEED v4: Building Operations + Maintenance Guide, LEED AP with specialty, LEED certification for existing buildings and spaces, LEED AP O+M Exam, Building Operations & Maintenance - Canada Green Building Council (CAGBC)
NEW QUESTION # 91
An organization pursuing LEED O+M certification for their headquarters has a renovation policy that includes strict requirements around the selection of building products and requires contractors working in the building to develop a plan for the diversion of waste produced during renovation projects. What must the organization add to their renovation policy to meet the requirements of Materials and Resources Prerequisite, Facility Maintenance and Renovation Policy?
- A. Requirements for the salvage and reuse of furniture within the building
- B. Requirements for contractors to safeguard air quality during renovation
- C. Requirements around the selection of low-emitting materials for renovation projects
- D. Requirements for contractors to perform construction activity pollution prevention
Answer: B
Explanation:
To meet the requirements of the Materials and Resources Prerequisite for Facility Maintenance and Renovation Policy, an organization must include provisions to protect indoor air quality during renovation activities. This includes implementing dust control measures, ensuring proper ventilation, and minimizing the release of pollutants. These requirements are essential for protecting the health and safety of building occupants during renovation projects.References:The Materials and Resources section of the LEED O+M Reference Guide discusses the components of a comprehensive Facility Maintenance and Renovation Policy, including the importance of safeguarding air quality during construction and renovation activities.
NEW QUESTION # 92
What is the diversion percentage of ongoing consumables in order to achieve exemplary performance as specified in Materials and Resources Credit, Solid Waste Management - Ongoing?
- A. 85%
- B. 90%
- C. 75%
- D. 50%
Answer: B
Explanation:
To achieve exemplary performance in the Materials and Resources Credit, Solid Waste Management - Ongoing, a diversion percentage of 90% for ongoing consumables is required. This high level of diversion demonstrates an advanced commitment to reducing waste and promoting recycling and composting. By diverting 90% of ongoing consumables from the landfill, projects significantly contribute to sustainability goals by minimizing their environmental footprint related to waste.
References:The LEED AP Operations + Maintenance reference guide specifies the criteria for exemplary performance in waste management, including the 90% diversion target. This ambitious goal underscores the importance of comprehensive waste reduction strategies in LEED-certified projects.
NEW QUESTION # 93
An ASHRAE Level 1 walkthrough analysis contributes to what prerequisite or credit?
- A. Energy and Atmosphere Prerequisite, Minimum Energy Performance
- B. Energy and Atmosphere Credit, Enhanced Refrigerant Management
- C. Energy and Atmosphere Prerequisite, Building-Level Energy Metering
- D. Energy and Atmosphere Prerequisite, Energy Efficiency Best Management Practices
Answer: D
Explanation:
An ASHRAE Level 1 walkthrough analysis is a preliminary evaluation of a building's energy systems to identify obvious energy efficiency opportunities and potential areas for improvement. This type of analysis aligns with the Energy Efficiency Best Management Practices by establishing a baseline understanding of the building's energy use and identifying simple, low-cost measures to improve energy efficiency. It does not directly relate to building-level energy metering, refrigerant management, or the minimum energy performance standards, which are more technical and specific in nature.
NEW QUESTION # 94
A LEED AP Operations and Maintenance project is at the end of the second month of the performance period when the team notices that the water meter readings for one of the two submeters is not being recorded. What advice should the LEED AP give the project team in order to comply with Water Efficiency Credit, Water Metering?
- A. Extend the performance period to gain the full three months of weekly water meter readings
- B. Remove the missing meter data from the credit upload
- C. Submit a Project CIR
- D. Use the incomplete data as is
Answer: A
Explanation:
The LEED AP O+M Reference Guide states that "If a meter fails during the performanceperiod, the project team must extend the performance period to obtain the required three months of data." Therefore, the best advice is to extend the performance period to gain the full three months of weekly water meter readings.
References:
* LEED AP O+M Reference Guide, Water Efficiency Credit, Water Metering, page 114
* LEED QUALIFICATION GUIDE - v4 - Sloan, page 2
* Building-Level Water Metering and Water Metering | LEEDuser
NEW QUESTION # 95
......
LEED-AP-O-M Exam Questions – Valid LEED-AP-O-M Dumps Pdf: https://www.prepawaypdf.com/USGBC/LEED-AP-O-M-practice-exam-dumps.html
LEED-AP-O-M Practice Test Questions Answers Updated 167 Questions: https://drive.google.com/open?id=1sJltkZbBwQF_Y3K_K3MJw_VOB2FsMq26