Authentic FlashArray-Implementation-Specialist Dumps - Free PDF Questions to Pass [Q13-Q30]

Share

Authentic FlashArray-Implementation-Specialist Dumps - Free PDF Questions to Pass

Guaranteed Accomplishment with Newest Sep-2025 FREE FlashArray-Implementation-Specialist


Pure Storage FlashArray-Implementation-Specialist Exam Syllabus Topics:

TopicDetails
Topic 1
  • Post-Installation
  • Upgrade: This section of the exam measures the skills of FlashArray Implementation Specialists and evaluates how professionals confirm system functionality after installation or an upgrade. It involves validating connectivity, running health checks, confirming configurations, and ensuring that the deployment meets operational expectations.
Topic 2
  • Upgrades: This section of the exam measures the skills of FlashArray Implementation Specialists and focuses on tasks involved in managing firmware and software upgrades. Candidates must demonstrate knowledge of upgrade planning, verification steps, and rollback procedures, ensuring that systems are updated with minimal disruption to service.
Topic 3
  • Installation: This section of the exam measures the skills of Enterprise Infrastructure Technicians and focuses on executing a successful installation of FlashArray systems. It tests the ability to perform physical setup, cabling, configuration of network settings, and the application of initial system configurations necessary for full deployment.
Topic 4
  • Pre-Installation
  • Upgrade: This section of the exam measures the skills of Enterprise Infrastructure Technicians and covers all preparation activities before deploying or upgrading a Pure Storage FlashArray. It includes understanding environmental requirements, verifying prerequisites, checking compatibility, and validating system readiness through appropriate tools and documentation.

 

NEW QUESTION # 13
An Implementation Engineer is scheduled to install a FlashArray and a DirectFlash Shelf (DFS).
What action should the Implementation Engineer perform?

  • A. Only upgrade the Purity on the FlashArray and then attach the DFS.
  • B. Refer to the "Recommended DFS Versions for Purity Releases" KB and upgrade Purity on the FlashArray and DFS.
  • C. Install the Array and DFS with the Purity that shipped and have Support upgrade remotely.

Answer: B

Explanation:
To ensure compatibility and optimal performance, the Implementation Engineer should consult the recommended DFS versions for the installed Purity release and upgrade both the FlashArray and DirectFlash Shelf accordingly.


NEW QUESTION # 14
When executing a FlashArray upgrade from the FA-405 to a FA-X Series, into which slot on CT1 must the 2 Port InfiniBand Card be installed?

  • A. 0
  • B. 1
  • C. 2

Answer: B

Explanation:
In the FlashArray//XR2 and //XR3 models, the 2-port InfiniBand card should be installed in PCIe slot 2 on controller CT1. This slot is designated for InfiniBand connectivity, ensuring optimal performance and compatibility during the upgrade process. Installing the card in the correct slot is crucial for maintaining proper system functionality and achieving the desired performance metrics.


NEW QUESTION # 15
Before leaving the site after an install, who is required to provide completion sign-off?

  • A. Customer
  • B. Account team
  • C. Support

Answer: A

Explanation:
The customer's completion sign-off is required to confirm that the installation meets their expectations and requirements before the engineer leaves the site.


NEW QUESTION # 16
For FlashArray//XL, which PCIe card slot is reserved for control upgrades?

  • A. 0
  • B. 1
  • C. 2

Answer: C

Explanation:
FlashArray//XL models are designed with 9 PCIe slots per controller, providing ample connectivity options for various components. Slot 5 is specifically reserved for non-disruptive upgrade (NDU) procedures, ensuring that controller upgrades can be performed without impacting system availability. This slot allocation is part of the system's design to facilitate seamless upgrades and maintain operational continuity.


NEW QUESTION # 17
When performing an install on a FlashArray, what step should be taken first?

  • A. CT0 configuration
  • B. CT1 configuration
  • C. Code upgrade

Answer: A

Explanation:
The installation process begins with configuring controller 0 (CT0) first, as it is the primary controller responsible for initial system setup.


NEW QUESTION # 18
Which command should an Implementation Engineer use to allow Support access to an array?

  • A. purearray connect --remoteassist
  • B. purearray remoteassist --connect
  • C. purearray remoteassist

Answer: B

Explanation:
The purearray remoteassist --connect command explicitly enables Support to establish a remote connection to the array for troubleshooting or assistance.


NEW QUESTION # 19
An Implementation Engineer is performing a capacity consolidation on an X50R3.
Which command is needed for the engineer to determine whether the customer's FlashArray supports SAS Flash Modules?

  • A. puredrive list --total --type controller
  • B. purehw list --type controller --all
  • C. purehw list --type drive --all

Answer: C

Explanation:
This command reports every installed drive module, identifying SAS Flash Modules if present, whereas the other commands do not enumerate individual drive types.


NEW QUESTION # 20
When should a FlashArray support case be opened?

  • A. Before starting install
  • B. Once an issue arises
  • C. Once install is completed

Answer: A

Explanation:
Opening a support case before starting the installation ensures timely assistance and coordination with support throughout the deployment process.


NEW QUESTION # 21
What hardware should the Implementation Engineer find in the upgrade kit in order to perform an //X to //XL NDU?

  • A. 4 QSFP cables / 2 Mellanox cards / 20 DFMDs
  • B. 2 QSFP cables / 3 Mellanox cards / 20 DFMDs
  • C. 3 QSFP cables / 4 Mellanox cards / 10 DFMDs

Answer: B

Explanation:
The upgrade kit for an //X to //XL Non-Disruptive Upgrade (NDU) includes 2 QSFP cables, 3 Mellanox InfiniBand cards, and 20 DirectFlash Modules (DFMDs) to support new hardware connectivity and capacity requirements.


NEW QUESTION # 22
What is the required PSU wattage for a FlashArray// X70R2/R3 or X90R2/R3 array?

  • A. 1200W
  • B. 1300W
  • C. 1600W

Answer: C

Explanation:
The FlashArray//X70R2 and //X90R2 models are equipped with dual 1600W power supplies, each rated for 1600 watts. These high-wattage power supplies are designed to support the increased performance and capacity demands of these models. The power supplies operate in an N+1 redundancy configuration, ensuring continuous operation even if one power supply fails.


NEW QUESTION # 23
Which action should an Implementation Engineer take to confirm that all volumes connected to a host are automatically in a protection group?

  • A. Add a new volume each time it is attached to the host.
  • B. Add a host as a member of a protection group.
  • C. Add the volumes as members of a protection group.

Answer: B

Explanation:
Adding the host itself to a protection group automatically includes all volumes connected to that host, ensuring comprehensive data protection without manual volume-by-volume assignment.


NEW QUESTION # 24
An Implementation Engineer is performing a capacity consolidation on an X50R2 that is 83% full. The starting config is X50R2-20/10-22/0. The end config is X50R2-91/0. What steps should the Implementation Engineer follow to complete the work?

  • A. Evac the chasses drives, install the new 91TB chassis data pack, and evac SH0.
  • B. Move the 20TB chassis DP to SH0, install the new 91TB chassis DP, evac the 10TB chassis DP, and evac SH0.
  • C. Evac SH0, evac the 20TB chassis DP, install the new 91TB DP, and evac the 10TB chassis DP.

Answer: A

Explanation:
The correct consolidation process involves evacuating data from the existing chassis drives first, then installing the new larger 91TB data pack, and finally evacuating shelf 0 to complete the consolidation efficiently.


NEW QUESTION # 25
Upon completion of a hardware upgrade activity, which command should be used to unset the maintenance tag?

  • A. purealert tag --cancel
  • B. purealert untag --maintenance
  • C. purealert --unset

Answer: B

Explanation:
The command purealert untag --maintenance removes the maintenance tag after a hardware upgrade, signaling the system that maintenance mode has ended.


NEW QUESTION # 26
After upgrading Purity during a new installation, which command should an Implementation Engineer run to determine what version of Purity will be loaded at the next boot of the FlashArray?

  • A. purearray list --controller
  • B. pureboot list
  • C. pureversion -a

Answer: B

Explanation:
The pureboot list command shows the versions of Purity installed and indicates which version will be loaded on the next system boot.


NEW QUESTION # 27
What are the interface names for a 4-port FC card in slot 1 in an XR2/3 array?

  • A. FC4, FC5, FC6, and FC7
  • B. FC0, FC1, FC2, and FC3
  • C. FC5, FC6, FC7, and FC8

Answer: A

Explanation:
On an XR2/3 array, a 4-port Fibre Channel card installed in slot 1 is assigned interface names FC4 through FC7, continuing the numbering sequence from other installed FC ports.


NEW QUESTION # 28
When installing the first DirectFlash Shelf on a FlashArray//XR2/3, what mezzanine ports are used on the controllers?

  • A. ETH7 and ETH9
  • B. ETH6 and ETH8
  • C. ETH6 and ETH9

Answer: C

Explanation:
When installing the first DirectFlash Shelf on a FlashArray//XR2/3, mezzanine ports ETH6 and ETH9 on the controllers are used for connectivity.


NEW QUESTION # 29
After running puredb run giveback --safe command once CT0 has been upgraded, how long should the Implementation Engineer wait before continuing with the controller upgrade?

  • A. 3 minutes
  • B. 10 minutes
  • C. 5 minutes

Answer: B

Explanation:
Waiting 10 minutes after running puredb run giveback --safe ensures the system completes safe resource rebalancing and stabilizes before proceeding with the next controller upgrade step.


NEW QUESTION # 30
......

FlashArray-Implementation-Specialist Braindumps PDF, Pure Storage FlashArray-Implementation-Specialist Exam Cram: https://www.prepawaypdf.com/Pure-Storage/FlashArray-Implementation-Specialist-practice-exam-dumps.html

Use Valid New Free FlashArray-Implementation-Specialist Exam Dumps & Answers: https://drive.google.com/open?id=1n1hGtgf1_EGbV1y0VmHutBAd1Nqf6Zis